DocumentaciónHelp

Rule catalog

Review detection rules in Sigma format, change their mode, test them against the last 24 hours, search back in time with them, and create custom rules.

On this page

Rules define what's suspicious. ARGUNIS includes rules from SigmaHQ (the open community of Sigma rules) and from ARGUNIS, and you can add your own (Custom). They all use the Sigma format.

Before you start

  • View permission in Security (SIEM) to review; Operate to test and search back in time; Administer to change modes, adjust thresholds, and create rules.

Review the rules

  1. Go to Security (SIEM) → Rules → Catalog.

  2. Filter by origin (SigmaHQ, ARGUNIS, Custom), by mode (Active, In observation, Off), or search by title, author, or technique.

  3. Read the columns: Level, event Source, ATT&CK techniques, Execution (Live, in seconds, or Scheduled), Det. 7 d, Retroactive (what the last search back in time found), and False + (percentage of false positive verdicts).

  4. Check Show helper rules to see the rules that are only used by other rules.

  5. Click a rule's title to see its details: description, mode, known false positives, which rules it uses and which use it, and its YAML.

Modes

Mode

What it does

Active

Fires detections, notifies, and opens cases according to severity

Observation

Fires marked detections, without notifying or opening cases. Useful for measuring a rule before activating it

Off

Doesn't run

To change it, choose the mode from the list in the Mode column.

Test a rule and search back in time

In the rule's details:

  • Test on the last 24 h: tells you how many times it would have fired and with how many events, without creating detections.

  • Search the stored days: runs the rule over the stored events and creates retroactive detections. These don't notify or open cases. When it finishes, click view retroactive detections.

ARGUNIS also searches back in time automatically when a rule is activated, created, or changed.

Adjust a correlation threshold

Correlation rules fire when something happens several times within a window (for example, 10 failed sign-ins in 5 minutes). To tune them for your company:

  1. Open the rule and click Adjust threshold….

  2. Change the Threshold or the Window. Leave a field empty to go back to the original value.

  3. Save. The details show the adjusted value and the original.

Create a custom rule

  1. Click Custom rule.

  2. Write the rule's YAML in Sigma 2.1, with the ARGUNIS OCSF fields. The Tab key inserts two spaces.

  3. Click Save. The rule starts in observation.

  4. Test it with Test on the last 24 h and, when you're satisfied, change it to Active.

Custom rules are edited with Edit and deleted with Delete from their details.

Cerebro suggestions

At the top of the catalog, Cerebro suggestions appear: exceptions proposed when a rule gives 80% or more false positives (with at least 10 verdicts) on an asset or group over 30 days. Cerebro only suggests: an administrator reviews the filter, the reason, and the expiration and clicks Accept…, or Dismiss.

SigmaHQ rules are used under the Detection Rule License (DRL) 1.1: each detection shows the rule's author.

Related

Search Argunis Monitoring

Type at least 2 characters to search Argunis Monitoring.

↑↓ to navigate · Enter to open · Esc to close